Gửi tin nhắn
Changzhou Trustec Company Limited

TRUSTEC MOTOR NHÀ MÁY TIN CẬY CỦA BẠN

Trang Chủ
Các sản phẩm
Về chúng tôi
Tham quan nhà máy
Kiểm soát chất lượng
Liên hệ chúng tôi
Yêu cầu báo giá
tin tức công ty
Nhà Sản phẩmĐộng cơ quạt ngưng

Multi Horse Condenser Fan Motor -1/3-1/6HP 1075RPM/2SPD Asynchronous Motor For Air Conditioner

Multi Horse Condenser Fan Motor -1/3-1/6HP 1075RPM/2SPD Asynchronous Motor For Air Conditioner

  • Multi Horse Condenser Fan Motor -1/3-1/6HP 1075RPM/2SPD Asynchronous Motor For Air Conditioner
  • Multi Horse Condenser Fan Motor -1/3-1/6HP 1075RPM/2SPD Asynchronous Motor For Air Conditioner
  • Multi Horse Condenser Fan Motor -1/3-1/6HP 1075RPM/2SPD Asynchronous Motor For Air Conditioner
Multi Horse Condenser Fan Motor -1/3-1/6HP 1075RPM/2SPD Asynchronous Motor For Air Conditioner
Thông tin chi tiết sản phẩm:
Nguồn gốc: Thường Châu, Trung Quốc
Hàng hiệu: trusTec
Chứng nhận: CE、High-tech Enterprise Certificate、ISO9000 Certificate 2023
Số mô hình: CTM5-465
Thanh toán:
Số lượng đặt hàng tối thiểu: 200 chiếc
Giá bán: Negotiable (FOB/CNF/CIF)
chi tiết đóng gói: Bao bì carton tiêu chuẩn, tấm xốp bên trong để bảo vệ.
Thời gian giao hàng: 15 ngày sản phẩm tươi sau khi xác nhận đơn hàng.
Điều khoản thanh toán: T/T, L/C
Khả năng cung cấp: 100.000 chiếc mỗi tháng
Tiếp xúc
Chi tiết sản phẩm

 

Product Name Condenser Fan Motor Voltage 208V/230V
Frequency 60Hz Output Power 1/3-1/6HP
Pole / AMPS 2.6/1.8A
Speed 1075RPM/2SPD Capacitor 370V
Insulation Class Class B

Power Factor

/
Other protection THERMALLY PROTECTED

 

Key Parameters

Model

Power

/HP

Frequency

/Hz

Speed

/RPM

Rated Current

/A

Voltage

/V

CTM5-465 1/3-1/6 60 1075/2SPD 2.6/1.8 208/230

Ps:all dimension can be customized according to customer requirement.

 

Multi Horse Condenser Fan Motor -1/3-1/6HP 1075RPM/2SPD Asynchronous Motor For Air Conditioner

 

Product Features

Residential and commercial condensing unit fan motors to meet manufacturer's requirements. 

  • Extended Studs
  • 1/2"*5" Leads
  • Hubless Lead End
  • Drain Holes Both Ends
  • Reversible Rotation
  • Designed for use with 370v Capacitors
  • Continuous Duty
  • Automatic Reset Thermal Overload Protector
  • Bearings have All Angle Thrust System
  • 140 F (60 C) Ambient
  • Class B Insulation

All trusTec Condenser Fan Motors feature reversible rotation and thru bolt or band mounting for air conditioning or heat pump applications.

 

Product Applications

1. Air conditioner indoor / outdoor unit.

2. Air Purifiers, Air refresher.

3. Range hood, sewer grinder, dehumidifier, medical equipment, special blender etc.

 

Our company

1. As a professional motor manufacturer, we are specialized in designing and producing all kinds of motors for room, commercial and central air conditioners.
2. Our main products are fan coil unit motors, motors for split, cabinet, window air-conditioner, high static pressure motors, ceiling air-conditioner motors, air cooling motors, single and three phase motors, kinds of pump motors, PG motor and DC brushless motors.
3. Our products have been approved by RoHS, CCC, CE and UL certificates, and the products have been being exported to the main market such as North America, Europe and Mid-east.

 

 

Learn More

 

The Condensor Fan Motor Guide – All You Need To Know

The AC condenser fan motor plays a major part in the successful operation of your HVAC system. Without proper maintenance it may wear,

 

resulting in a poor air flow and unstable heating and cooling conditions. These motors are designed with balanced rotors to help reduce noise and

 

vibrations during use.

 

What is a condensor fan motor?

 

The AC condenser fan motor plays a major part in the successful operation of your HVAC system. Without proper maintenance it may wear,

 

resulting in a poor air flow and unstable heating and cooling conditions. These motors are designed with balanced rotors to help reduce noise and

 

vibrations during use.

 

How do I know if my condensor fan motor is bad?

 

Overheating can be an issue with air condition+ing units and when your unit is hot to touch, you know there is an issue that needs addressing.

 

Any problems with the condenser fan motor can lead to your AC unit overheating, and this is probably the best place to start looking. With regular

 

cleaning and maintenance, the condenser fan motor should run smoothly. You should always consult a qualified contractor to maintain and check

 

your fan motor, as they usually need specific oils to keep working.

 

What happens when a condenser fan motor fails?

 

When the motor fails, your AC unit will become hot and emit a slight odor. It will stop pushing out cold air and could damage your air conditioning

 

unit. When this happens, it is best to shut it down and call an engineer.

 

What causes a condenser fan motor to fail?

 

There are many reasons it may fail, with the most common being, a lack of lubricant, a failed bearing in the belt drive, water in the windings,

 

voltage problems or a failed run capacitor.

 

Why is my AC fan making a noise?

 

If a fan becomes loose or needs cleaning it will start to hum or rattle. Open up your air conditioning unit, locate the fan motor and check to make

 

sure it is clean with no debris around the blades. Occasionally, bits of dirt or insulation may become loose and fall onto the blades. So, keeping it

 

clean will help to keep it working properly.

 

Other ways to fix a noisy fan include

 

  • Tightening the blade screws
  • Examine the blades to make sure they are not bent or unbalanced
  • Secure the fan motor canopy
  • Lubricate the condenser fan motor
  • Clean the blades and vents

How to replace a condensor motor fan

 

Switch off the power supply and turn the blades round. If they do not spin smoothly and are not obstructed or bent, then it is likely to be the motor

 

that needs replacing.Here are 7 factors to be noted before buying a new fan motor.

  • The mounting – they are not all the same
  • Shaft size
  • RPM speed
  • Rotation direction of shaft
  • Motor measurements
  • Horsepower rating
  • Voltage

 

Before removing anything, you must make sure all power is disconnected and unplugged. The make a note of all the existing wiring conditions.

 

Take a photograph to remind yourself of what colors go where.

 

Unscrew all bolts that hold the motor in place and remove the fan blade, making a note of how it attaches to the shaft.

 

Now replace with the new motor and re-attach the fan blade in the same way you took it off.

 

It is always advisable to replace the air conditioning unit’s run capacitor, following all the advice above, copying wiring, color coding and

 

installation. Unscrew it from the unit and replace the capacitor with a new one that matches the technical information of the old one. Sometimes

 

they will come in different shapes and sizes, but if you have the right technical details, you cannot go wrong.

 

Chi tiết liên lạc
Changzhou Trustec Company Limited

Người liên hệ: Ms. Selena Chai

Tel: +86-13961191626

Fax: 86-519-85109398

Gửi yêu cầu thông tin của bạn trực tiếp cho chúng tôi (0 / 3000)

Sản phẩm khác